Forums

hamad.koroni
Have a pedestrian footbridge crossing the highway road and am looking for the NFPA code that tells the fire and life safety requirements for this kind of facility?  The footbridge is an above-ground structure with a horizontal length of about 100m and 6m wide. The footbridge contains one elevator and one stair opens to the sky at each end of the… (Show more)
in Building & Life Safety
jcsalas
BUENOS DIAS, EN ALGUNA NORMA NFPA INDICA LA OBLIGATORIEDAD DE PINTAR LAS TUBERIAS DE LA RED DE AGUA CONTRA INCENDIOS DE COLOR ROJO ?
in Fire Protection Systems
homevisionin
main lug subpanel  I was working on a 200 amp panel and I came across a sub-panel 8 space 8 circuit maxed out  that has an overcurrent protection 2 pole 30 amp with a 10/3wire  the 200 amp is maxed out.     Q: wherein the code# NFPA 70# dose it mentions the minimum conductor size for sub-panel?#    P.S i checked in article 408 
in Electrical
mekara28
Click to view contentHello Sir or Ma'm,   Please find below the above-below sprinkler connection detail on site. My client has rejected this application according to NFPA 13 8.15.20.4.3. Please tell me my application is correct or not?
in Code Enforcement
louiselarkin
Clause 10.2.1.4, NFPA 58 Any space beneath the floor shall be solid fill, or the perimeter of the space shall be left entirely unenclosed   I am looking for some clarification on this clause and how it relates to a partially enclosed (concrete walls but open to sky) LPG enclosure.  The enclosure is located above a basement car park.     Thanks… (Show more)
in Building & Life Safety
hfontana
Just want some feedback from other sprinkler companies on what software they are using. 
in Fire Protection Systems
thomas.crozier
I am an electrician at a VA health care facility. I was recently tasked with doing a Relocatable Power Tap (RPT) audit of all of our patient care rooms. I understand that the area within 6 feet of where the patient receives care the RPT has specific requirements for the type of RPT and the equipment it can support. My question is specific to the… (Show more)
in Electrical
reza.sabet
Hi, I would like to know the requirements and equations I need to use based on NFPA codes, to : 1) Size the Explosion relieving Devise , i.e., Explosion Panel or Explosion Hatch for Starch Siloes used in Pulp& Paper Mills to store Starch. I am interested i8n knowing the requirement for adding these devises for Existing Bolted Siloes or New Siloes.… (Show more)
in Industrial Hazards
sub3marathonman
Hoping to hear some opinions about the dilemma.   Situation:  A home entertainment center, which now has an uninterruptible power supply.  The UPS is currently plugged into an outlet, definitely acceptable.  However, on occasion I want to move the UPS to a different location.  These occasions are very rare, until now not every 90 days.  When I… (Show more)
in Electrical
dfcarter
My facility has in house Sprinkler, Extinguisher, Fire Door, Fire Pump, Fire Alarm, ETC.. testing that at the moment we print off our reports on MIcrosoft Word document and bring with us then come back to the office to manually enter the changes. Is there a program out there being used by a contractor or in house inspector like myself that we can… (Show more)
in Code Enforcement
alexanderbeum
This question pertains to a skilled nursing facility in Northern California.   We clean out our dryers and vents once a month. We recently signed up for TELS, a software program specific for this industry distributed by Direct Supply. The sign up process has different inspections/logs and frequency recommendations for them. The TELS system is… (Show more)
in Building & Life Safety